21 Penn Plaza

360 West 31st Street, New York, New York
Borough:
Manhattan
Neighborhood:
Midtown
Rentable Sqft(k):
375
Floors:
17
Built:
1931
Available ISPs
Carrier Cable Type Network Type Distribution Level Point of Entry
Broadview Fiber Type 2 - Internet Service Provider riding another company’s cables Full Distribution via Verizon
Spectrum Coaxial Phone or Cable company network Full Distribution aerial POE - Floor 2 of Firetower
Spectrum Fiber Type 1 - fiber carrier network with owned cables entering building Full Distribution aerial POE - Floor 2 of Firetower
Verizon Copper Phone or Cable company network Full Distribution 9th Ave and 31st St
Verizon Fiber Type 1 - fiber carrier network with owned cables entering building Full Distribution 9th Ave and 31st St
Building Infrastructure
Building has multiple points of entry (protected conduit locations) for telecom wiring No
Building locates telecommunications equipment in a... Shared closet or room
Is there spare capacity to install new telecommunications equipment in the building? Yes
Building has riser space that goes from the basement to the top floor in a closed, protected environment? Yes
Building risers can easily support service delivery from the addition of any new ISPs within the current infrastructure (without additional build out work)? Yes
Building has two or more diverse riser locations? Yes
Readiness
Building has signed Point of Entry Agreements (POEs) in place with carriers? Yes - for all carriers
Does building management have a boilerplate agreement in place? Yes
Does building management have the capability to bring in additional new service providers into the building to cover new service requirements demanded by tenants? Yes
Additional Telecom Information
In public areas, is public wifi available? No
Is there a Distributed Antenna System (DAS) in place for cell phone service? No
Do the building's Points Of Entry enter from different sides of the property? (e.g. North, South, East, West) No
Do you have a first responder system in place? Fire Department Approved System
Do the carriers in your building offer Central Office diversity? No
Is telecommunications equipment in your building located above grade (to prevent possible damages from flooding)? No
Have you or your service providers implemented any Green / Sustainability measures for reducing the environmental impact of the connected building provisions at this location? Yes